A210
ExtruStrong (Alcoa) | Extruded profile
Manufacturer-reported values. Do not use as certified design allowables. View sources ↗
| Temper | Wall | Yield MPa | Tensile MPa | Elong. % |
|---|---|---|---|---|
| T6 | ≤ 5 mm | 375–400 | 390–400 | ≥ 12 |
T6 condition: Achievable mechanical properties strongly depend on extrusion, quench and aging processes. The source reports a thickness limit of ≤5 mm, not a thickness interval.
Chemical composition
Reported weight-percent bounds. A blank lower bound means only an upper threshold was reported.
Alcoa reports ExtruStrong technical-data chemistry in wt%. Single values are maxima, and the sheet says chemistry can be customized to meet customer needs; these entries are not universal certified limits. Source abbreviations OE and OT remain unpublished pending definition.
| Element / source label | Minimum wt% | Upper wt% |
|---|---|---|
| Si | 0.5 | 1.2 |
| Fe | 0.1 | 0.5 |
| Cu | 0.1 | 1 |
| Mn | 0.05 | 0.5 |
| Mg | 0.5 | 1.5 |
| Cr | 0.05 | 0.5 |
| Zn | — | 0.1 |
| Ti | — | 0.1 |
Physical and thermal properties
| Property | Reported value | Unit | Condition |
|---|---|---|---|
| No reviewed physical or thermal claim for this record. | |||
Evidence
Alcoa Specialty Alloys: A210 ExtruStrong Technical Data — Alcoa Corporation
Show the exact source location for each value
- alcoa-a210-t6 — PDF p. 2, MECHANICAL PROPERTIES, A210 ExtruStrong T6 row and note ↗
- Si — PDF p. 2, CHEMICAL COMPOSITION, Si column ↗
- Fe — PDF p. 2, CHEMICAL COMPOSITION, Fe column ↗
- Cu — PDF p. 2, CHEMICAL COMPOSITION, Cu column ↗
- Mn — PDF p. 2, CHEMICAL COMPOSITION, Mn column ↗
- Mg — PDF p. 2, CHEMICAL COMPOSITION, Mg column ↗
- Cr — PDF p. 2, CHEMICAL COMPOSITION, Cr column ↗
- Zn — PDF p. 2, CHEMICAL COMPOSITION, Zn column ↗
- Ti — PDF p. 2, CHEMICAL COMPOSITION, Ti column ↗